Detail Fluke 87-5 Digital Multimeter
Naryanatekindo Jual Fluke 87-5 Digital Multimeter. information specification voltage DC Maximum Voltage : 1000V Accuracy : Fluke 83 V : ± ( 0 , 1 % + 1 ) Fluke 87V : ± ( 0 , 05 % + 1 ) Maximum resolution : Fluke 83 V : 100 ¼ V Fluke 87 V : 10 ¼ V AC voltage Maximum Voltage : 1000V Accuracy : Fluke 83 V : ± ( 0 , 5 % + 2 ) Fluke 87 V : ± ( 0 , 7 % + 2 ) True RMS Fluke 83 V AC Bandwidth : 5KHz Fluke 87 V : 20kHz * * With a low pass filter , 3dB @ 1kHz Maximum resolution : 0 , 1 mV DC current Maximum Amps : 10A ( 20 A for 30 seconds maximum ) Amps Accuracy : Fluke 83 V : ± ( 0 , 4 % + 2 ) Fluke 87 V : ± ( 0 , 2 % + 2 ) Maximum resolution : Fluke 83 V : 0 , 01 mA Fluke 87 V : 0 , 01 ¼ A AC current Maximum Amps : 10A ( 20 A for 30 seconds maximum ) Amps Accuracy : Fluke 83 V : ± ( 1 , 2 % + 2 ) Fluke 87 V : ± ( 1 , 0 % + 2 ) True RMS Maximum resolution : 0 , 1 ¼ A resistance Maximum Resistance : 50 MQ Accuracy : Fluke 83 V : ± ( 0 , 4 % + 1 ) Fluke 87 V : ± ( 0 , 2 % + 1 ) Maximum resolution : 0.1 © capacitance Maximum Capacitance 9999 ¼ F Accuracy ± ( 1 % + 2 ) Maximum resolution of 0 , 01 nF frequency Maximum frequency of 200 kHz Accuracy ± ( 0 , 005 % + 1 ) Maximum resolution of 0 , 01 Hz Duty cycle Maximum Duty Cycle 99 , 9 % Accuracy ± ( 0 , 2 % per kHz + 0.1 % ) Maximum resolution of 0 , 1 % temperature measurement Fluke 87 V , 87 V / E : -200 , 0 ° C - 1090 ° C -328 , 0 ° F - 1994 ° F 0 including investigation 80 BK Temperature Probe -40 , 0 ° C - 260 ° C -40 , 0 ° F - 500 ° F , 2 , 2 ° C or 2 % whichever is greater conductance Maximum conductance of 60.00 nS Accuracy ± ( 1 , 0 % + 10 ) Maximum resolution of 0 , 01 nS diode Range : 3 V Resolution : 1 mV Accuracy : ± ( 2 % + 1 ) Duty Cycle Range Accuracy : Within ± ( 0 , 2 % per kHz + 0 , 1 % ) Environmental specifications Operating Temperature -20 ° C to + 55 ° C temperature Storage -40 ° C to + 60 ° C Humidity ( Without Condensation ) 0 % - 90 % ( 0 ° C - 35 ° C ) 0 % - 70 % ( 35 ° C - 55 ° C ) altitude Operation 2000 m Safety specifications overvoltage category EN 61010-1 to 1000 V CAT III , 600V CAT IV Agency Approvals UL , CSA , Tu V , VDE listed Mechanical & General Specifications size 201 x 98 x 52 mm ( with holster ) weight 355 g Weigh With Holster and Flex - Stand 624 g show Digital : 6000 update number 4 / sec . ( Model 87 also has 19, 999 amount in high -resolution mode . ) Analog : 32 segments , updates 40 / sec . Frequency : 19, 999 number , update 3 / sec at > 10 Hz . assurance Lifetime Battery Life Alkaline : ~ 400 hours typical , without backlight shock 1 meter drop per IEC 61010-1 : 2001 vibration Per MIL - PRF - 28800 for Class 2 instrument
Tampilkan Lebih Banyak