Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Barat

Bergabung Selama :

BAGIKAN :   

Bagikan :

Fluke 87-5 Digital Multimeter

Update Terakhir
:
14 / 12 / 2022
Min. Pembelian
:
1 Buah
Dilihat Sebanyak
:
3 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Fluke 87-5 Digital Multimeter

Naryanatekindo Jual Fluke 87-5 Digital Multimeter. information specification voltage DC Maximum Voltage : 1000V Accuracy : Fluke 83 V : ± ( 0 , 1 % + 1 ) Fluke 87V : ± ( 0 , 05 % + 1 ) Maximum resolution : Fluke 83 V : 100 ¼ V Fluke 87 V : 10 ¼ V AC voltage Maximum Voltage : 1000V Accuracy : Fluke 83 V : ± ( 0 , 5 % + 2 ) Fluke 87 V : ± ( 0 , 7 % + 2 ) True RMS Fluke 83 V AC Bandwidth : 5KHz Fluke 87 V : 20kHz * * With a low pass filter , 3dB @ 1kHz Maximum resolution : 0 , 1 mV DC current Maximum Amps : 10A ( 20 A for 30 seconds maximum ) Amps Accuracy : Fluke 83 V : ± ( 0 , 4 % + 2 ) Fluke 87 V : ± ( 0 , 2 % + 2 ) Maximum resolution : Fluke 83 V : 0 , 01 mA Fluke 87 V : 0 , 01 ¼ A AC current Maximum Amps : 10A ( 20 A for 30 seconds maximum ) Amps Accuracy : Fluke 83 V : ± ( 1 , 2 % + 2 ) Fluke 87 V : ± ( 1 , 0 % + 2 ) True RMS Maximum resolution : 0 , 1 ¼ A resistance Maximum Resistance : 50 MQ Accuracy : Fluke 83 V : ± ( 0 , 4 % + 1 ) Fluke 87 V : ± ( 0 , 2 % + 1 ) Maximum resolution : 0.1 © capacitance Maximum Capacitance 9999 ¼ F Accuracy ± ( 1 % + 2 ) Maximum resolution of 0 , 01 nF frequency Maximum frequency of 200 kHz Accuracy ± ( 0 , 005 % + 1 ) Maximum resolution of 0 , 01 Hz Duty cycle Maximum Duty Cycle 99 , 9 % Accuracy ± ( 0 , 2 % per kHz + 0.1 % ) Maximum resolution of 0 , 1 % temperature measurement Fluke 87 V , 87 V / E : -200 , 0 ° C - 1090 ° C -328 , 0 ° F - 1994 ° F 0 including investigation 80 BK Temperature Probe -40 , 0 ° C - 260 ° C -40 , 0 ° F - 500 ° F , 2 , 2 ° C or 2 % whichever is greater conductance Maximum conductance of 60.00 nS Accuracy ± ( 1 , 0 % + 10 ) Maximum resolution of 0 , 01 nS diode Range : 3 V Resolution : 1 mV Accuracy : ± ( 2 % + 1 ) Duty Cycle Range Accuracy : Within ± ( 0 , 2 % per kHz + 0 , 1 % ) Environmental specifications Operating Temperature -20 ° C to + 55 ° C temperature Storage -40 ° C to + 60 ° C Humidity ( Without Condensation ) 0 % - 90 % ( 0 ° C - 35 ° C ) 0 % - 70 % ( 35 ° C - 55 ° C ) altitude Operation 2000 m Safety specifications overvoltage category EN 61010-1 to 1000 V CAT III , 600V CAT IV Agency Approvals UL , CSA , Tu V , VDE listed Mechanical & General Specifications size 201 x 98 x 52 mm ( with holster ) weight 355 g Weigh With Holster and Flex - Stand 624 g show Digital : 6000 update number 4 / sec . ( Model 87 also has 19, 999 amount in high -resolution mode . ) Analog : 32 segments , updates 40 / sec . Frequency : 19, 999 number , update 3 / sec at > 10 Hz . assurance Lifetime Battery Life Alkaline : ~ 400 hours typical , without backlight shock 1 meter drop per IEC 61010-1 : 2001 vibration Per MIL - PRF - 28800 for Class 2 instrument
Tampilkan Lebih Banyak