Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Barat

Bergabung Selama :

BAGIKAN :   

Bagikan :

Fluke 101 Basic Digital Multimeter

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0
Dilihat Sebanyak
:
11 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Fluke 101 Basic Digital Multimeter

Basic dc accuracy 0.5% CAT III 600 V safety rated Diode and continuity test with buzzer Small lightweight design for one-handed use Rugged, durable design Automatic shutdown Battery is easy to replace Electrical Specifications V AC ( 40-500Hz) Range 600.0 mV 6.000 V 60.00 V 600.0 V Resolution 0.1 mV 0.001 V 0.01 V 0.1 V Accuracy 3.0% ± 3 digit 1.0% ± 3 digit V DC Range 6.000 V 60.00 V 600.0 V Resolution 0.001 V 0.01 V 0.1 V Accuracy 0.5% ± 3 digit Resistance Ohms Range 400.0 & 4.000 k& 40.00 k& 400.0 k& 4.000 M& 40.00 M& Resolution 0.1 & 0.001 k& 0.01 k& 0.1 k& 0.001 M& 0.01 M& Accuracy 0.5 % ± 3 digit 0.5 % ± 2 digit 0.5 % ± 2 digit 0.5 % ± 2 digit 0.5 % ± 2 digit 1.5% ± 3 digit Capacitance Range 50.00 nF 500.0 nF 5.000 ¼ F 50.00 ¼ F 100.0 ¼ F Resolution 0.01 nF 0.1 nF 0.001 ¼ F 0.01 ¼ F 0.1 ¼ F Frequency ( 10 Hz – 100 kHz) Range 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz Resolution 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz Duty Cycle Range 0.1 % to 99.9 % Resolution 0.1 % General Specifications CAT Rating CAT III 600 V V AC Range 600.0 V V DC Range 600.0 V Ohms Range 40.00 M& Auto Shutoff Y Continuity Y Capacitor 100.0 ¼ F Frequency 100.0 kHz Hold No Duty Cycle Yes Size 130 mm x 65 mm x 27mm Weight 160 g Battery Two AAA Warranty 1 year Environmental Specifications Operating Temperature 0 ° C to + 40 ° C Storage Temperature -30 ° C to + 60 ° C Operating Humidity Non condensing ( < 10 ° C) < = 90% RH ( at 10 ° C to 30 ° C) < = 75% RH ( at 30 ° C to 40 ° C) ( Without Condensation) Operating Humidity, 40 M& 80% RH 10 ° C to 30 ° C, 70% RH 30 ° C to 40 ° C Operating Altitude 2, 000 meters Storage Altitude 12, 000 meters IP Rating IP 40 per IEC 60529 Vibration Requirements MIL-PRF-28800F, Class 2 Drop Test Requirements -10° C and 1 meter to surface, per IEC-61010-1, and Fluke SOP 39.1 for portable Hand-held equipment Shipping container drop per Fluke SOP 39. EMI, RFI, EMC Must meet all applicable requirements in IEC/ EN 61326-1 Absorption/ Corrosion Per Fluke SOP 39.1 Temperature Coefficients Add 0.1 x specified accuracy for each degree C above 28 ° C or below 18 º C Model Name Description Fluke 101 Includes: Fluke 101 Basic Digital Multimeter Tl75 Hard Point Test Lead Set Two AAA Batteries ( Installed) Fluke 101 Kit Includes: Fluke 101 Basic Digital Multimeter Tl75 Hard Point Test Lead Set Two AAA Batteries ( Installed) Smart Strap Fluke 101 / i400E Clamp Bundle Includes: Fluke 101 Basic Digital Multimeter Fluke i400E AC Current Clamp Tl75 Hard Point Test Lead Set Current Clamps Fluke i400E Fluke i400E AC Current Clamp Test Leads TL75 TL75 Hard Point™ Test Lead Set
Tampilkan Lebih Banyak